LX Steam97
Version 1.0 · Shuhei Miyake
Description
LX Steam is a System Manager-compliant program that calculates the thermodynamic properties of steam and water based upon the recent IAPWS-IF97 formulations. Copyrighted freeware.
Technical details
- File
st97_100.zip- Size
- 30.0 KB
- Format
- .zip
- Year
- 2001
- Added to S.U.P.E.R.
- 2001-09-24
- Files inside
- 3
- Author
- Shuhei Miyake
- Path
anonftp/pub/st97_100.zip
How to install it
What to send to the palmtop saves 3.5 KB
These are the files you need. You can send them from the package contents below.
-
steam97.exm→ A:\SOFT aplicación del System Manager 54.0 KB -
steam97.icn→ A:\SOFT icono, junto a su aplicación 200 B
No need to put
steam97e.txt:
they are manuals, source code or supporting material. Read them here and save 3.5 KB on a 1 MB disk.
Steps
- Copy steam97.exm to A:\SOFT. It is a System Manager application: register it in App Manager with F2 (Add), giving the full path (for example A:\SOFT\steam97.exm).
- The 200LX takes 8 EXM applications at most. Check with F8 (List) in App Manager: an asterisk in the Status column means the quota is full and you will need MoreEXM.
- The .ICN files are icons: they go in the same folder as their application.
Derived from the package contents and the 200LX conventions. It installs to A: on purpose: C: is a RAM disk and every byte there is memory taken from the system.
The author's instructions
----- Installation
This archive includes following files.
STEAM97E.TXT ..... This file
STEAM97.EXM ..... Executable file
STEAM97.ICN ..... Icon file
Unzip .EXM and .ICN files, and register STEAM97.EXM to the System Manager.
At the first execution, STEAM97 automatically creates a STEAM97.ENV file
in A:\_DAT directory. If you don't have a: drive, then c:\_DAT is assigned
instead.
----- How to Use
1.Enter temperature and pressure, then press [F10]. Steam/water properties
then be displayed.
The possible range of input value is displayed by pressing [F1] key.
The unit system of input values is assumed that now on display.
2.You can select the unit sets by checking [UnitSet] menu in the menu bar.
When selecting multiple sets, you can change the unit set by [F9] key,
at any time.
At the first execution of the program, SI(C) and Metric are selected.
3.To calculate the saturation, enter either temperature or pressure and the
other field should leave blank. In this case, the pressure or temperature
must be below the critical point.
4.To calculate wet steam, enter temperature and quality or pressure and
quality. The quality (%wetness) is identified by a suffix 'x' or 'X' at
the other field.
ex) Temp[180 ] Press[2.5x ] <- 180deg-C and 2.5% quality
5.To calculate properties from pressure and enthalpy, enter the enthalpy data
at Temp field. The enthalpy is identified by a suffix 'h' or 'H'.
ex) Temp[800h ] Press[120 ] <- 800kcal/kg and 120kg/cm2a
** Caution **
If the entered enthalpy and pressure belongs region 3, a dialog will
appear to confirm wheter continue or cancel calculation because it will
take several minutes to finish. During the calculation, you can't switch
…
Literal excerpt from steam97e.txt, exactly as it came in the package.
Package contents
Send to my palmtop
The palmtop must be waiting before you press the button, or the transfer will fail. It is the palmtop that announces it is ready, not the other way round.
Your browser cannot talk to the serial port. Direct sending uses the Web Serial API, which only exists in Chrome, Edge and Opera on desktop — not in Firefox, Safari or any mobile browser.
Download the file with the button above and copy it to the palmtop your usual way.