LX Steam is a System Manager-compliant program that calculates the thermodynamic properties of steam and water based upon the recent IAPWS-IF97 formulations. Copyrighted freeware.

Ficha técnica

Fichero
st97_100.zip
Tamaño
30.0 KB
Formato
.zip
Año
2001
Alta en S.U.P.E.R.
2001-09-24
Ficheros dentro
3
Autor
Shuhei Miyake
Ruta
anonftp/pub/st97_100.zip

Cómo instalarlo

Qué enviar al palmtop ahorras 3.5 KB

Estos son los ficheros que necesitas. Puedes enviarlos desde el contenido del paquete.

  • steam97.exm → A:\SOFT aplicación del System Manager 54.0 KB
  • steam97.icn → A:\SOFT icono, junto a su aplicación 200 B

No hace falta llevar al palmtop steam97e.txt: son manuales, código fuente o material de apoyo. Léelos aquí y ahórrate 3.5 KB en un disco de 1 MB.

Pasos
  1. Copia steam97.exm a A:\SOFT. Es una aplicación del System Manager: regístrala en App Manager con F2 (Add), indicando la ruta completa (por ejemplo A:\SOFT\steam97.exm).
  2. El 200LX admite 8 aplicaciones EXM como máximo. Comprueba con F8 (List) en App Manager: si ves un * en la columna Status, tienes el cupo lleno y necesitarás MoreEXM.
  3. Los .ICN son iconos: van en la misma carpeta que su aplicación.

Deducido del contenido del paquete y de las convenciones del 200LX. Se instala en A: a propósito: C: es un disco RAM y cada byte ahí resta memoria al sistema.

Instrucciones del autor
----- Installation
This archive includes following files.
    STEAM97E.TXT  ..... This file
    STEAM97.EXM   ..... Executable file
    STEAM97.ICN   ..... Icon file

Unzip .EXM and .ICN files, and register STEAM97.EXM to the System Manager.
At the first execution, STEAM97 automatically creates a STEAM97.ENV file
in A:\_DAT directory.  If you don't have a: drive, then c:\_DAT is assigned
instead.


----- How to Use
1.Enter temperature and pressure, then press [F10].  Steam/water properties
  then be displayed.
  The possible range of input value is displayed by pressing [F1] key.
  The unit system of input values is assumed that now on display.

2.You can select the unit sets by checking [UnitSet] menu in the menu bar.
  When selecting multiple sets, you can change the unit set by [F9] key,
  at any time.
  At the first execution of the program, SI(C) and Metric are selected.

3.To calculate the saturation, enter either temperature or pressure and the
  other field should leave blank.  In this case, the pressure or temperature
  must be below the critical point.

4.To calculate wet steam, enter temperature and quality or pressure and
  quality.  The quality (%wetness) is identified by a suffix 'x' or 'X' at
  the other field.
  ex) Temp[180         ]  Press[2.5x       ]   <- 180deg-C and 2.5% quality

5.To calculate properties from pressure and enthalpy, enter the enthalpy data
  at Temp field.  The enthalpy is identified by a suffix 'h' or 'H'.
  ex) Temp[800h        ]  Press[120        ]   <- 800kcal/kg and 120kg/cm2a

  ** Caution **
  If the entered enthalpy and pressure belongs region 3, a dialog will
  appear to confirm wheter continue or cancel calculation because it will
  take several minutes to finish. During the calculation, you can't switch
…