S.U.P.E.R. Archivo HP 200LX
← Volver al catálogo

Fuzzy Logic

Versión 2.02 · Xcentrics Inc

Descargar 192.5 KB

Descripción

The HP Palmtop Paper Artificial Intelligence: FuzzyOne : Development System For Fuzzy Logic. Shareware but apparently abandoned.

Ficha técnica

Fichero
fuzzy.zip
Tamaño
192.5 KB
Formato
.zip
Año
1997
Alta en S.U.P.E.R.
1999-10-13
Ficheros dentro
15
Autor
Xcentrics Inc
Ruta
anonftp/pub/fuzzy.zip

Cómo instalarlo

Qué enviar al palmtop ahorras 300.7 KB

Estos son los ficheros que necesitas. Puedes enviarlos desde el contenido del paquete.

  • ENDIT.COM → A:\SOFT programa de DOS 418 B
  • FUZZYONE.EXE → A:\SOFT programa de DOS 197.3 KB
  • GET.COM → A:\SOFT programa de DOS 86 B
  • INTOFF.COM → A:\SOFT programa de DOS 87 B
  • PUT.COM → A:\SOFT programa de DOS 14 B

No hace falta llevar al palmtop ART.FUZ, ARTICLE.DOC, DEMO.FUZ, DEMO.GET, DEMO.PUT, ENDIT.ASM, FUZZ.ONE, INTOFF.ASM y 2 más: son manuales, código fuente o material de apoyo. Léelos aquí y ahórrate 300.7 KB en un disco de 1 MB.

Pasos
  1. Copia ENDIT.COM, FUZZYONE.EXE, GET.COM, INTOFF.COM a A:\SOFT. Son programas de DOS: se ejecutan desde el icono DOS, o añadiendo A:\SOFT al PATH de C:\AUTOEXEC.BAT para poder llamarlos por su nombre.

Deducido del contenido del paquete y de las convenciones del 200LX. Se instala en A: a propósito: C: es un disco RAM y cada byte ahí resta memoria al sistema.

Instrucciones del autor
setup data are changed on one, it is automatically transferred to the
  other.  Requirements are

        The extension's setup data (that is, address, access type, and
       if it is an input/output) must be the same as the one being
       extended.  The graph name must be different.
        Each input can be extended once.  An extension cannot be
       extended.
        When extensions are created or removed, a message is displayed.
        During simulation, an extension receives the same input as the
       extended graph automatically.   The graph used is the first
       encountered.  Only one input value is displayed at the top of
       manual simulation's output graph.  In automatic simulation,
       either graph can be used as the input.
        Outputs cannot be extended.
        When defining rules, extensions are viewed as separate entities
       (if it is not specified, it is not used).
        In the learn file, the extension's data is included.
        If extensions exist, they are specified in both the printout
       (File menu, selection F3) and display graph/shape data (Standard
       menu, selection F8).
        Inputs and outputs can have the same address and access type
       without being considered extensions.
        To delete extensions, change the graph's address, access type,

     20     Graphing





       or remove the entire graph.

  See the Tutorial (Chapter 2) for an example of setting up an
  extension.
















































                                                          Graphing     21





                                  NOTES
































     22     Graphing





                             Chapter 4 - Rules


…

Extracto literal de MANUAL.TXT, tal cual venía en el paquete.

Enviar a mi palmtop

El palmtop tiene que quedar esperando antes de pulsar el botón, o la transferencia fallará. Es él quien avisa de que está listo, no al revés.

¿Primera vez? Cómo conectar el palmtop, paso a paso →